Gas chromatography is a powerful analytical technique that involves vaporizing the sample in the injection port and carrying it through a column using a carrier gas. As the sample components travel through the column, they are separated based on their different affinities for the stationary phase. Once separated, the compounds are sequentially detected, allowing the instrument to generate a signal for each component. This process enables both qualitative and quantitative analysis of the sample.
In addition to identifying and quantifying substances, gas chromatographs can also be used to determine various physical and chemical properties, such as partition coefficients, activity coefficients, molecular weight, and specific surface area. These parameters provide valuable insights into the behavior of the sample within the stationary phase.
When operating a gas chromatograph, there are three key factors that should not be overlooked:
1. **Gas Purity**
Gas chromatographs require high-purity gases, typically above 99.99%. However, many operators fail to recognize that different detectors may have varying requirements for gas purity. Using low-purity gases can lead to issues like unstable baselines or excessive noise. For example, if 98% hydrogen is used instead of higher purity gas in a detector operating at 104 MΩ sensitivity, the baseline may become highly unstable, resulting in continuous peaks. Additionally, impurities in the carrier gas, such as trace oxygen, can shorten the lifespan of capillary columns.
2. **Gas Flow Ratios**
When using a flame ionization detector (FID), the correct ratio of nitrogen, hydrogen, and air is essential for optimal performance. The flame must be properly ignited and maintained in an oxygen-rich environment to ensure complete combustion of hydrogen. The ideal ratio is usually Air: H₂ = 6–8:1, and N₂: H₂ = 1:0.85–1, with more air being preferable. Maintaining these ratios ensures stable and sensitive detection, which is crucial for accurate quantification and reliable correction factors.
3. **Environmental Conditions**
Gas chromatographs do not require extreme temperature control but generally operate best between 5°C and 35°C. Humidity levels should be kept between 20% and 85%. In high-humidity areas, excessive moisture can reduce the insulation performance of the instrument, leading to decreased sensitivity. If this occurs, appropriate measures—such as using desiccants or controlling the environment—should be taken to maintain the accuracy and reliability of the results.
By paying attention to these factors, users can ensure consistent and accurate performance from their gas chromatograph, making it a valuable tool in analytical chemistry.